{"product_id":"rossmax-ne100-nebuliser","title":"ROSSMAX NE100 NEBULISER","description":"\u003ch2\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rossmax NE100 Piston Nebulizer is a powerful Piston compressor with consistent fine particle size for efficient respiratory treatment. The nebulizer is intended for use in treatment of asthma, COPD and other respiratory ailments in which an aerosolized medication is required during therapy. It has an economic design, a 2-in-1 cup for easy cleaning, assembly and disassembly and also has a 3 year warranty. The MMAD is ≤2.6 μm, the Fine Particle Dose (FPD)is 80-85% and the Nebulization Rate is ≥ 0.30 ml\/min.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAsthma\u003c\/em\u003e: Asthma becomes apparent by frequent, spasmodic gasping for air and wheezing. As with chronic bronchitis, the bronchi are inflamed and obstructed with phlegm while the cilia are conglutinated. The respiratory passages also respond to certain stimuli with muscular spasms, often caused by allergens such as pollen or house dust, but also stress and environmental pollution.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eChronic Obstructive Pulmonary Disease (COPD)\u003c\/em\u003e: Chronic obstructive pulmonary disease is a type of obstructive lung disease characterized by long-term poor airflow. The main symptoms include shortness of breath and cough with sputum production. COPD is a progressive disease, meaning it typically worsens over time. Eventually everyday activities, such as walking up stairs, become difficult. Chronic bronchitis and emphysema are older terms used for different types of COPD.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eE\u003cspan\u003efficient Respiratory\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e: Utilizing the new technologies to improve the management and treatment of asthma, COPD and other respiratory conditions. With nebulizer systems, patients have the ability to effectively manage and treat their respiratory condition anywhere, anytime.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Rossmax NE100 Piston Nebulizer comes with the following accessories:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAir tube\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir filters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstruction Manual\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMasks for adult and child\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNebulizer kit, mouthpiece\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eUses\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Rossmax Piston Nebulizer is intended for use in treatment of asthma, COPD and other respiratory ailments in which an aerosolized medication is required during therapy. Treatments are delivered quickly, safely and conveniently making this unit ideal for all ages in health care structures like hospitals and home care.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlease read the instruction manual before use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAssembling your nebulizer kit:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the cleaning instructions prior to using your nebulizer for the first time or after it has been stored for an extended period of time\u003c\/li\u003e\n\u003cli\u003eAlways unplug the compressor and make sure the power switch is turned to the “OFF” position before cleaning, assembling and before or after each use\u003c\/li\u003e\n\u003cli\u003ePlace the compressor on a flat, stable surface within reach\u003c\/li\u003e\n\u003cli\u003eGently twist and pull straight up on the lid of the nebulizer kit to separate into two parts (medication cup and cover)\u003c\/li\u003e\n\u003cli\u003eThe stem inside the medication cup inserts into the tube of the nozzle\u003c\/li\u003e\n\u003cli\u003eAdd the prescribed amount of medication to the medication cup\u003c\/li\u003e\n\u003cli\u003eReassemble the nebulizer kit by carefully twisting the medication cup and cover together, making sure that the two parts fit securely\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eOperating your nebulizer:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe nebulizer kit is operable at up to a 45° angle – if the angle is greater than 45°, no aerosol will be generated\u003c\/li\u003e\n\u003cli\u003eAttach one end of the air tube connector to the air output\u003c\/li\u003e\n\u003cli\u003eCarefully attach the opposite end of the air tubing connector to the stem at the base of the nebulizer kit\u003c\/li\u003e\n\u003cli\u003eAttach the angled mouthpiece or mask to the top of the nebulizer kit\u003c\/li\u003e\n\u003cli\u003eThe capacity of the medication cup is 2~5 ml.\u003c\/li\u003e\n\u003cli\u003eNOTE: A 30-minute interval is recommended after each use.\u003c\/li\u003e\n\u003cli\u003eThe compressor will automatically shut off if it becomes overheated. If \/ when this happens, immediately press the power-switch to the “OFF” position, unplug the power cord from the outlet and allow the motor to cool for 30 minutes. Before restarting the unit, make sure that the air vents are not obstructed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAfter every use:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUnplug the unit from the power source\u003c\/li\u003e\n\u003cli\u003eAllow the unit to completely cool\u003c\/li\u003e\n\u003cli\u003eCarefully detach the air tubing from the nebulizer and pour out any remaining medication\u003c\/li\u003e\n\u003cli\u003eFollow the cleaning procedures provided\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCleaning procedures:\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eRinsing technique (performed after each treatment or before first use)\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMake sure that the power-switch has been turned to the “OFF” position and the unit has been disconnected from the power source\u003c\/li\u003e\n\u003cli\u003eDisconnect the air tube from the nebulizer device\u003c\/li\u003e\n\u003cli\u003eGently twist and pull up the cover of the nebulizer kit to open and separate\u003c\/li\u003e\n\u003cli\u003eRinse the nebulizer kit and components with hot tap water\u003c\/li\u003e\n\u003cli\u003eDry with clean towels or completely air dry\u003c\/li\u003e\n\u003cli\u003eReassemble the nebulizer kit\u003c\/li\u003e\n\u003cli\u003eNote: When cleaning for the first time or if the unit has been stored for an extended period of time, thoroughly clean all components, except the air tube. The nebulizer kit is dishwasher safe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCleaning the compressor:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWipe the compressor daily using a soft cloth – any other form of cleaning or cleaning agents may damage the finish of the unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eChanging the air filter:\u003c\/em\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIt is important to change the air filter when the air filter turns grey – It is recommended to change air filter every 2 months.\u003c\/li\u003e\n\u003cli\u003eRemove the air filter cover by gently pulling forward\u003c\/li\u003e\n\u003cli\u003eDiscard the grey filter\u003c\/li\u003e\n\u003cli\u003eReplace with a new, clean air filter\u003c\/li\u003e\n\u003cli\u003eSecurely re-attach the air filter cover to the unit.\u003c\/li\u003e\n\u003cli\u003eNote: Air filters cannot be cleaned or washed. Only NE100 air filters can be used. Do not substitute alternate material such as cotton. Do not operate without an air filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eTroubleshooting:\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIf any abnormality occurs during use, please check and correct the following:\u003c\/p\u003e\n\u003cp\u003e1.Unit does not operate when power switch is pressed:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the AC connection to the outlet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e2.No misting or low rate of misting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck that there is medication in the nebulizer cup.\u003c\/li\u003e\n\u003cli\u003eCheck the main unit if there is any physical damage.\u003c\/li\u003e\n\u003cli\u003eCheck the position of the nozzle inside the nebulizer.\u003c\/li\u003e\n\u003cli\u003eMake sure that air tube and other components are properly attached.\u003c\/li\u003e\n\u003cli\u003eCheck the air filter and replace if necessary\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"firstaidshop.ie","offers":[{"title":"Default Title","offer_id":56867665445244,"sku":"NEBULISER002","price":75.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0854\/4714\/7809\/files\/ROSSMAX_NEBULISER_NEBULIZER_NE100.png?v=1781263494","url":"https:\/\/firstaidshop.ie\/products\/rossmax-ne100-nebuliser","provider":"firstaidshop.ie","version":"1.0","type":"link"}